Experience with CIRCULAR CAST-IN-PLACE PRESTRESSED CONCRETE TANKS
designed in accordance with the AWWA D115-95 Standard or its Predecessors

Designed by: Jorgensen & Close Associates
Owner
Location
Client
(If Not Owner)
Date Bid (B)
Completed (C)
or
Negotiated (N)
Size
in MG
Remarks
Cost in
Dollars
Cost
¢/Gallon
City of Englewood, CO
1973 (C)
6.0 Horizontal and vertical post-tensioned with tendons; won in alternate bidding competition with strand wrapped and wire wrapped shotcrete with steel diaphragm; part buried, includes excavation and backfill; post-tensioned roof.

$536,000

8.9

City of Arvada, CO
80th & Simms, Arvada, CO
Wright-McLaughlin Engineers

1974 (C)
10.0 Horizontal and vertical post-tensioned with tendons; was $5,000 higher than strand wrapped alternate, but was selected by contractor and owner due to advantages in wintertime constructability; buried, includes excavation and backfill, post-tensioned roof with tennis courts; includes all landscaping.

$860,000 8.6

Ken Caryl Ranch Water District
Littleton, CO
Wright-McLaughlin Engineers

1975 (C) 2@
2.0
Horizontal and vertical post-tensioned with tendons; buried, includes excavation and backfill; post-tensioned roof. Won in alternate bidding competition with wire- and strand-wrapped wall designs. Higher price includes some rock excavation.

$283,000
&
$293,000
14.1
&
14.6
Ken Caryl Ranch Water District
Littleton, CO
Wright-McLaughlin Engineers

1975 (C) 5.0 Horizontal and vertical post-tensioned with tendons; buried, includes excavation and backfill; post-tensioned roof. Won in alternate bidding competition with wire- and strand-wrapped wall designs.

$580,000 11.6
City of Spokane, WA
Atlas Prestressing

1976 (C)
Design-Build
6@
2.6
Horizontal and vertical post-tensioned with tendons; part buried; open top; secondary clarifiers.

See
summary
below

City of Spokane, WA
Atlas Prestressing

1976 (C)
Design-Build
3@
2.4
Horizontal and vertical post-tensioned with tendons; part buried; dome roof; anaerobic digesters.

See
summary
below

City of Spokane, WA
Atlas Prestressing

1976 (C)
Design-Build
3@
0.3
Horizontal and vertical post-tensioned with tendons; part buried; open top; gravity thickeners.

See
summary
below

Spokane Tank Project Summary

The tendon design for the 12 Spokane tanks noted above, saved $1,800,000 for the owner compared to strand-wrapped alternates designed by others. The solitary $4,000,000 bid received on the strand wrapped tanks had been declared invalid by the EPA (who was partially funding the project) because of lack of fair competition. The contractor then invited nationwide proposals from tank designers and prestressing firms. The tendon tank design by our firm won. (Contact J&CA for a brief article reprinted from Engineering News Record about this savings.)

$2,200,000
Total for
walls only
9.3 Avg.
City of Carbondale, CO
Wright-McLaughlin Engineers
April
1976 (B)
2.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof. Won in alternate bidding competition with wire- and strand-wrapped wall designs.

$255,000 12.8
City of Louisville, CO
Louisville WTP
Atlas Prestressing
Rocky Mountain Consultants, Inc.
Civil Engineers
August 1976 (B)
Design-Build
3.0 Horizontal and vertical post-tensioned; with a post-tensioned roof; won in a design / build competition with a steel tank and a reinforced concrete tank with a precast roof. We designed the post-tensioned structural floor as a consultant to Atlas. The pier-supported floor was required due to site conditions. The tank is above ground.

$313,000 10.4
Centennial Water District
Highlands Ranch, CO
Meurer and Associates

1976 (C)
(Wall Analysis)
4.0 Computer structural analysis of the post-tensioned wall for design by others.

Not
Applicable
Salt Lake County Water District
Salt Lake City, UT
Atlas Prestressing
1976 (C)
Design-Build
3.0 Horizontal and vertical post-tensioned; part buried includes excavation and backfill; post-tensioned roof and floor.

$345,000 11.5
City of West Jordan, UT
Atlas Prestressing
1976 (C)
Design-Build
2.0 Horizontal and vertical post-tensioned; part buried, includes excavation and backfill; post-tensioned roof and floor.

$230,000 11.5
Southgate Water District
Littleton, CO
Meurer and Associates

1976 (C)
(Wall Analysis)
2.0 Computer structural analysis of the post-tensioned wall for design by others.

Not
Applicable
City of Loveland, CO
M&I, Inc. Consulting Engineers
1977 (C)
(Rehabilitation)
3.0 Horizontal post-tensioned tendon repair of a distressed wire-wrapped tank originally designed by others.

Not
Applicable
Eastman Kodak Company
Windsor, CO
March
1977 (B)
3.0 Horizontal and vertical post-tensioned with tendons; not buried; includes $80,000 architectural precast concrete; post-tensioned roof. Won in alternate bidding competition with wire- and strand-wrapped wall designs.

$333,000 11.1
East Larimer Co. Water District
Fort Collins, CO
M&I, Inc. Consulting Engineers
April
1977 (B)
2.5 Horizontal and vertical post-tensioned with tendons; buried, includes excavation and backfill; post-tensioned roof.
Won in alternate bidding competition with wire and strand-wrapped wall designs.

$279,000 11.2
East Larimer Co. Water District
Fort Collins, CO
M&I, Inc. Consulting Engineers
April
1977 (B)
1.0 Horizontal and vertical post-tensioned with tendons; buried, includes excavation and backfill; post-tensioned roof.
Won alternate bidding competition with wire- and strand-wrapped wall designs.

$146,000 14.6
City of Canon City, CO
M&I, Inc. Consulting Engineers
September
1977 (B)
4.0 Horizontal and vertical post-tensioned; part buried, includes excavation and backfill; post-tensioned roof.

$439,000 11.0
E. Cherry Cr. Valley Water &
San. Dist.
Aurora, CO
Meurer and Associates
1977 (C)
(Wall Analysis)
1.0 Computer structural analysis of the post-tensioned wall for design by others.



Not
Applicable
Denver Water Board
Denver, CO
DMJM-Phillips Reister
March
1978 (B)
10.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof. Owner selected three circular post-tensioned 10 M.G. tanks for this site in lieu of two rectangular conventionally reinforced 15 M.G. tanks proposed by others.

$1,225,856 12.3
City of Brigham City
Brigham City, UT
VSL Corporation

1978 (C)
Design-Build
5.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof and floor.
Seismic Zone 3.

$860,000 17.2
Town of Telluride, CO
Wright-McLaughlin Engineers
September
1978 (B)
0.75 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof. Won in alternate bidding competition with wire- and strand-wrapped wall designs.

$174,000 23.2
Keystone Resort
Summit County, CO
Meurer and Associates
1978 (C)
(Wall Analysis)
1.5 Computer structural analysis of the post-tensioned wall for design by others.


Not
Applicable
Mt. Werner Water and Sanitation
District
Steamboat Springs, CO
Wright-McLaughlin Engineers
January
1979 (B)
1.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof. Won in alternate bidding competition with wire- and strand-wrapped wall designs.

$307,000 30.7
Ft. Collins / Loveland,
Water District
Windsor, CO;
Donath Lake Phase I
M&I, Inc. Consulting Engineers
February
1979 (B)
2.0 Horizontal and vertical post-tensioned; buried, includes rock excavation and backfill; post-tensioned roof. Won in alternate bidding competition with wire- and strand-wrapped wall designs.

$347,000 17.4
National Park Service
Yellowstone National Park, WY
Wright-McLaughlin Engineers
August
1979 (B)
1.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof. Won in alternate bidding competition with wire- and strand-wrapped wall designs.

$408,524 40.8
Roxborough Water and San.
Littleton, CO
Wright-McLaughlin Engineers
March
1980 (B)
1.0 Horizontal and vertical post-tensioned; buried, includes rock excavation and backfill; post-tensioned roof.

$296,000 29.6
National Park Service
Yellowstone National Park, WY
Wright-McLaughlin Engineers
May
1980 (B)
1.6 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof.

$400,965 25.1
Battlement Mesa Inc.
Parachute, CO
Wright-McLaughlin Engineers
July
1980 (B)
1.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof.

$294,535 29.5
Ft. Collins / Loveland Water
District
Ft. Collins, CO
M&I Inc. Consulting Engineers
October
1980 (B)
4.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof.

$640,220 16.0
Willows Water District
Englewood, CO
Meurer and Associates

1980 (C)
(Wall Analysis)
5.25 Computer structural analysis of the post-tensioned wall for design by others.

Not
Applicable
City of Albuquerque, NM
Walker Reservoir
Gordon Herkenhoff & Associates
March
1981 (B)
6.5 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof and floor. Won in alternate bidding competition with a steel tank.

$1,105,000 17.0
Castle Pines Metropolitan Dist.
Castle Rock, CO
Taranto, Stanton & Tagge
May
1981 (N)
(Negotiated)
2.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof and floor.

$500,000 25.0
Battlement Mesa Inc.
Parachute, CO
Wright-McLaughlin Engineers
July
1981 (B)
3.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof and floor.

$623,850 20.8
E. Cherry Cr. Valley Water and
San. Dist.
Aurora, CO
Meurer and Associates
1981 (C)
(Wall Analysis)
5.0 Computer structural analysis of the post-tensioned wall for design by others.


Not
Applicable
City of Fraser, CO
Rocky Mountain Engineers
July
1982 (B)
1.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof.

$295,000 29.5
National Park Service
U.S. Dept. of Interior
Yellowstone National Park
Wright-McLaughlin Engineers
August
1982 (B)
0.75 Horizontal and vertical post-tensioned; buried, includes $25,000 worth of rock excavation and backfill; post-tensioned roof.


$470,000 62.7
Southgate Water Dist.
Littleton, CO
Meurer and Associates
1982(C)
(Wall Analysis)
6.0 Computer structural analysis of the post-tensioned wall for design by others.


Not
Applicable
Snowmasss Water and
Sanitation District
Snowmass at Aspen, CO
Mclaughlin Water Engineers,
Ltd.
May
1983 (B)
1.0 Horizontal and vertical post-tensioned; buried with up to 8.5 feet of backfill on post-tensioned tank roof sloped to accommodate the ski run this tank is located in; includes excavation and backfill ($104,000 included for the special sheet pile shoring, dirtwork and under-drain, required due to poor earth-work conditions and site constraints); post-tensioned floor.

$430,274 43.0
Parkville Water District
Leadville, CO
W.W. Wheeler & Associates
May
1983 (B)
1.0 Horizontal and vertical post-tensioned; buried, includes $33,000 excavation (done in 1982) and backfill; post-tensioned roof.

$275,289 27.5
Town of Silverthorne, CO
Mclaughlin Water Engineers, Ltd.
May
1983 (B)
1.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof and floor.

$344,777 34.5
Denver Water Board
Littleton, CO
Meheen Engineering Corp.
June
1983 (B)
(Reviewed)
10.0 Computer analysis and wall design review and modifications of "V" shaped tendon design by others. Post-tensioned roof and floor. Includes $423,000 excavation and backfill (buried) excludes $359,000 piping, valves and miscellaneous.

$1,779,000 17.8
Town of Castle Rock, CO
Cornerstone Builders, Inc.
February
1984 (B)
Design-Build
0.5 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof and floor. The post-tensioned tank was preferred by the owner over a conventionally reinforced tank alternate, which was bid $5,000 less by the same contractor.

$183,277 36.7
Stonegate Center Metropolitan
District
Parker, CO
Greiner Engineering
July
1984 (B)
2.5 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof and floor.

$474,300 19.0
Castle Pines North Metropolitan
District
Castle Rock, CO
Taranto, Stanton and Tagge
July
1984 (N)
(Negotiated)
2.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof and floor.

$584,000 29.2
Green Mountain Water & Sanitation
District
Lakewood, CO
McLaughlin Water Engineers, Ltd.
February
1985 (B)
1.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; a post-tensioned, drilled pier supported, structural concrete floor was required due to swelling soil conditions at the site; post-tensioned roof.

$400,000 40.0
Town of Castle Rock, CO
McLaughlin Water Engineers
June
1986 (B)
2.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof and floor.

$444,000 22.2
Meadows Metropolitan District
No. 1
Castle Rock, CO
Taranto, Stanton and Tagge
July
1986 (B)
3.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof and floor.


$509,500 17.0
City of Golden, CO
N. Table Mountain, Golden, CO
McLaughlin Water Engineers
February
1987 (B)
2.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned roof and floor.

$376,115 18.8
Consolidated Mutual Water Co.
N. Table Mountain, Golden, CO
McLaughlin Water Engineers
April
1987 (B)
2.0 Horizontal and vertical post-tensioned; buried, includes rock excavation and backfill; post-tensioned roof and floor.

$387,200 19.4
National Park Service
Grand Canyon National Park, AZ
Mclaughlin Water Engineers
August
1987 (N)
(Negotiated)
1.0 Horizontal and vertical post-tensioned; partially buried, rock excavation; Chemically treated exterior color to blend in with the scenery.

Not
Available
Ciba-Geigy Chemical Company
McIntosh, AL
VSL Corporation
March
1988
(Rehabilitation)
3.5 Investigation and rehabilitation of distressed emergency holding tank for hazardous wastes, designed by others. Horizontal and vertical post-tensioned wall, post-tensioned floor, open top. This tank is fiberglass lined to withstand anything with a pH between 2 & 12. Cost shown is for the post-tensioned concrete floor and wall only.

$236,000 6.7
Ciba-Geigy Chemical Company
McIntosh, AL
VSL Corporation
March
1988
(Rehabilitation)
2@
0.5
Investigation and rehabilitation of distressed floors (due to subgrade settlement) of thickener tanks for treatment of hazardous waste, designed by others. Horizontal and vertical post-tensioned wall, conventionally reinforced floor and open top. Cost shown is for post-tensioned concrete floors and walls only.

2@
$81,000
16.2
Ciba-Geigy Chemical Company
McIntosh, AL
VSL Corporation
March
1988
(Rehabilitation)
3@
0.85
Investigation and rehabilitation of distressed floors (due to subgrade settlement) of clarifier tanks for treatment of hazardous wastes, designed by others. Horizontally and vertical post-tensioned wall, conventionally reinforced floor and open top.

3@
$102,000
12.0
Ciba-Geigy Chemical Company
McIntosh, AL
VSL Corporation
March
1988
(Reviewed)
2.5 Review and modification to the design of a storm water detention tank, designed by others, prior to construction. Horizontal and vertical post-tensioned wall, post-tensioned floor and open top. Cost shown is for the post-tensioned concrete and floor and wall only.

$202,000 8.1
Ciba-Geigy Chemical Company
McIntosh, AL
VSL Corporation
March
1988
(Reviewed)
2.0 Review and modification to the design of a storm water detention tank, designed by others, prior to construction. Horizontal and vertical post-tensioned wall, post-tensioned floor and open top. Cost shown is for the post-tensioned concrete and floor and wall only.

$146,000 7.3
Hillsdale Powell Utility District
Knoxville, TN
VSL Corporation
April
1988
(Reviewed)
1.2 Review and modification to the design of a clarifier tank, designed by others, prior to construction. Horizontal and vertical post-tensioned wall, post-tensioned floor, open top.

$226,000 18.8
Trinity River Authority
Grand Prairie, TX
VSL Corporation
April
1988
(Reviewed)
2@
1.4
Review and modifications to the design of digester tanks, designed by others, prior to construction. Post-tensioned wall with "V" shaped tendons. Conventionally reinforced floor. These tanks were built inside distressed and abandoned wire-wrapped tanks, using the old walls as exterior forms. Fiberglass dome roof (not included in the cost.)

2@
$185,000
13.2
Triview Metropolitan District
Monument, CO
KKBNA, Inc.
April
1988
(Reviewed)
1.5 Review and modifications to the design of a water tank, designed by others, prior to construction. Horizontal and vertical post-tensioned wall, post-tensioned floor and roof.

Not
Applicable
Snowmass Water and San.
District
Snowmass at Aspen, CO
McLaughlin Water Engineers
July
1988 (B)
1.0 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned floor and roof, soil cover varied from 2 ft. to 15 ft. to blend in with the existing topography, requiring steeped footings and roof slabs.

$446,752 44.7
Consolidated Mutual Water Co.
Green Mountain, Golden, CO
McLaughlin Water Engineers
August
1988 (B)
0.8 Horizontal and vertical post-tensioned; buried; post-tensioned floor and roof slabs.


$225,000 28.1
Superior Metropolitan District
Superior, CO
McLaughlin Water Engineers
October
1988 (B)
1.4 Horizontal and vertical post-tensioned; buried, includes excavation and backfill; post-tensioned floor and roof. Floor and roof had additional post-tensioned reinforcement to withstand potential foundation movements.

$343,321 24.5
Snowmass Water and San.
District
Ridgerun Tank
Snowmass at Aspen, CO
McLaughlin Water Engineers
June
1989 (B)
1.0 Horizontal and vertical post-tensioned wall; post-tensioned roof slab; post-tensioned mat foundation as the floor slab; buried with soil cover varying from 4' to 17'-6" to blend in with the existing topography of the site. This required stepped floor and roof slabs, includes excavation and backfill.

$645,000 64.5
Lookout Mountain Water
District
Chief Hosa Storage Reservoir
Jefferson County, CO
July
1989 (B)
1.0 Horizontal and vertical post-tensioned wall; post-tensioned floor and roof slabs; buried with no soil cover on the roof slab; price includes rock excavation, backfill and some piping. Owner paid $100,000 additional in first costs for the buried post-tensioned concrete tank in alternate bidding competition with a used steel tank when he considered the present worth of repainting costs, aesthetic value and other advantages of buried concrete reservoir.

$347,000 34.7
City of Albuquerque, NM
Simms Reservoir
Bohannan-Huston, Inc.
January
1990 (B)
7.0 Horizontal and vertical and post-tensioned wall; buried; post-tensioned floor and roof. Price includes "normal" excavation and backfill; price does not include about 3.04/gal. worth of rock excavation, over-excavation of collapsible soils and replacement with select backfill below the tank. The owner declined our recommendation for a strand-wrapped wall alternate due to prior poor performance of a strand-wound tank designed by others and good experience with a prior tendon tank we designed. A distressed, above ground, wire-wound tank formerly serving this zone was demolished when this tank was finished.

$1,290,000 18.4
City of Salida, CO
McLaughlin Water Engineers
August
1990
(Rehabilitation)
1.0 Horizontal post-tensioned repair of a distressed wire-wrapped tank originally designed by others.

Not
Applicable
Perdue Farms, Inc.
Accomac, VA
VSL Corporation
October
1990
(Reviewed)
2@
4.0
Review and modifications to the design of waste sludge tanks designed by others, prior to construction. Horizontal and vertical post-tensioned wall, post-tensioned floor and open top.

$400,000 10.0
Cities of Englewood and
Littleton, CO
Bi-City WWTP,
Englewood, CO
Dywidag Systems International,
USA
Brown &Caldwell
(Civil Engineer)
December
1990 (B)
Design-Build
2@
2.0
Horizontal and vertical post-tensioned walls, above grade with a broken fin exterior architectural finish except for a white finish at external launder and brick veneer at the base of the walls. Conventionally reinforced floor slab and wall footing was designed by others, except for effects of fixed base wall connection. Won in "contractor design" competition with other tendon suppliers and tank designers.

Not
Available
(Bid as part of a $25,000,000 WWTP expansion project.)

See Fall, 1996 for cost information on identical tanks.

Perdue Farms, Inc.
Accomac, VA
VSL Corporation
December
1990
(Reviewed)
2.5 Review and modifications to the design of a clarifier tank designed by others, prior to construction. Horizontal and vertical post-tensioned wall, post-tensioned floor, open top.

$285,000 11.4
Wampler Longacre Poultry
Harrisonburg, VA
VSL Corporation
February
1991
(Reviewed)
0.7 Review and modification to the design of a clarifier tank designed by others, prior to construction. Horizontal and vertical post-tensioned wall, post-tensioned floor and post-tensioned top.

$135,000 19.3
West Lynn Creamery Digesters
Lynn, MA
VSL Corporation
May
1991
(Reviewed)
1.8
and
0.2
Review and modifications to the design of an anaerobic digester tank designed by others, prior to construction. Horizontal and vertical post-tensioned walls, post-tensioned floor and open top. A major wire-wound tank builder bid $225,000 higher for the same work.

$515,000 28.6
Manenggon Hills Golf Resort
Guam, U.S.A.
Dames & Moore, Denver, CO
June
1991 (B)
1.5 Horizontal and vertical post-tensioned wall; partially buried; conventionally reinforced floor and roof slabs. Contains the days effluent from the wastewater treatment plant for spreading over the golf course at night.

Not
Available
(Bid as part of a $15,000,000 WWTP project)

Manenggon Hills Golf Resort
Guam, U.S.A.
Dames & Moore, Denver, CO
Pending
need for
treatment
capacity
0.3 Horizontal and vertical post-tensioned wall; buried; conventionally reinforced floor, open top with concrete launder trough; clarifier for WWTP.

Not
Applicable
City of Boulder, CO
and Pine Brook Water District
Boulder, CO
McLaughlin Water Engineers
July
1991 (B)
4.1
and
0.6
Horizontal and vertical post-tensioned walls; buried with backfill sloping up from 2 feet to 10 feet deep over the roof; post-tensioned floor and roof slabs. Price includes excavation and backfill, price does not include $74,460 for over excavation and lime stabilization of up to 25 feet of soft clay under 1/2 of the tank base. The owner elected to build a tank-within-a-tank in order to not commingle water supplies while sharing the same limited site.

$974,664
for a 4.1 MG Tank

$97,042
for a 0.6 MG Wall
23.8
and
16.2
Uwchlan Township Municipal
Authority
Exton, PA
Terre Hill Concrete Products Co.
Gannett Fleming, Inc.
(Civil Engineer)
October
1991 (B)
Design-Build
2.0 Horizontal and vertical precast, post-tensioned walls; buried to within 5 feet of the top of the wall; post-tensioned floor and roof slabs. Price includes structural engineering fee. Price does not include $153,000 (7.7 ¢/gal.) for excavation and backfill.

$645,000 32.3
Texas Instruments Corp.
McKinney, TX
Texas Instruments Corp.
VSL Corporation (Engineer)
March
1992
(Rehabilitation)
3.0 Investigation and rehabilitation of seepage through the wall of a circular prestressed concrete tank with cast-in-place core wall, originally designed by others.

Not
Applicable
Birdsboro Borough
Berks County, PA
Terre Hill Concrete Products
Keystone Engineering
(Civil Engineer)
March
1992 (B)
Design-Build
1.4 Horizontal and vertical post-tensioned, precast walls; lowest 3 feet buried; post-tensioned floor and roof slabs. Price includes excavation, backfill and structural engineering fee.

$339,600 24.3
City of Albuquerque, NM
Ponderosa Reservoir #2
URS Consultants
February
1993 (B)
6.0 Horizontally and vertically post-tensioned walls; buried, with 3 feet of backfill over the post-tensioned two-way flat-plate roof; post-tensioned floor slab. Price includes excavation and backfill, stubbed-out piping and appurtenances.

$1,465,900 24.4
Montaire Farms of DelMarVa
Selbyville, Delaware
April
1993
(Investigation)
0.5 Peer review and modifications to the design of a circular prestressed concrete wastewater treatment tank designed by others prior to construction.

Not
Applicable
Town of Silverthorne, CO
Golden Eagle Road
McLaughlin Water Engineers
June
1995 (B)
0.5 Horizontally and vertically post-tensioned wall; with 3 feet of backfill over the post-tensioned two-way flat plate roof; post-tensioned floor slab. Price includes excavation and backfill, stubbed out piping and appurtenances.

$287,022 57.4
Town of Castle Rock, CO
Green Zone II Tank
Meurer and Assoc., Structural Engr.
August
1995
(Review)
2.0 Review and modifications to the design and details of the post-tensioned concrete water tank. Horizontally and vertically post-tensioned wall with post-tensioned floor and two-way flat plate roof.

Not
Applicable
Indianapolis Water Co.
South Well Field Backwash
Tank
HNTB, Structural Engr.
February
1996
(Review)
0.3 Review and modifications to the design and details of the circular post-tensioned concrete backwash water tank. Horizontally and vertically post-tensioned floor and two-way flat plate roof.
The owner hired us to assist HNTB in copying our typical design developed for circular prestressed concrete water tanks.

Not
Applicable
City of Broomfield, CO
GWRRP WTP, Backwash Tank
Centric / Jones, Constructors
February
1996
(Rehabilitation)
1.0 Investigation and rehabilitation of distressed post-tensioned concrete tank originally designed by others. The radially post-tensioned floor slab had failed below the center column during the initial stressing operation.

Not
Applicable
City of Westminster, CO
Semper WTP, Clearwell
Centric / Jones, Constructors
May
1996
(Rehabilitation)
5.0 Investigation and rehabilitation of distressed and leaking post-tensioned concrete tank originally designed by others. Floor slab had failed around a 5'-0" diameter pipe.

Not
Applicable
Cities of Englewood and
Littleton, CO
Bi-City WWTP,
Englewood, CO
Brown & Caldwell
Fall
1996 (B)
1@
2.0

1@
1.5
Horizontal and vertical post-tensioned walls, above grade tanks. Price includes broken fin exterior architectural concrete finish, (except white finish at external launder and brick veneer at wall base). Conventionally reinforced floor slab and integral wall footing designed by Brown & Caldwell, except for the effects of the fixed base wall connection. Open top.

$561,600
$95,600
(Exc. & Backfill)

$417,628
$132,121
(Exc. & Backfill)
28.1
4.8



27.2
8.8
City of Broomfield, CO
Interlocken Golf Course
HDR Engineers
March
1997 (B)
6.0 Horizontally and vertically post-tensioned wall; buried, with up to 4 feet of backfill over the post-tensioned two-way flay plate roof; post-tensioned floor slab. Price includes excavation and backfill, stubbed-out piping and appurtenances. Price does not include about $90,000 for 10 ft. of lime-treated structural fill below the tank. This tank was designed for H-20 truck loads as it is buried under a public golf course.

$1,320,00 22.0
Town of Castle Rock, CO
Purple Zone Tank
McLaughlin Water Engineers
July
1997 (B)
1.0 Horizontal and vertical post-tensioned wall; partially buried, includes excavation and backfill; post-tensioned roof and membrane floor.

$512,951 51.3
CBP Resources, Inc.
Fayetteville, NC
D.W. Burt Concrete
Construction, Inc.
September
1997 (B)
Design-Build
2.2 Horizontal and vertical post-tensioned wall. Above grade, does not include site preparation. Open top clarifier.

$245,000 11.1
CBP Resources, Inc.
Fayetteville, NC
D.W. Burt Concrete
Construction, Inc.
September
1997 (B)
Design-Build
0.4 Horizontal post-tensioned only; conventionally reinforced vertically. Above grade, does not include site preparation. Open top gravity thickener.

$108,00 27.0
Grain Processing Corporation
Washington, Indiana
Bowen Engineering
Corporation, G.C.
January
1998 (B)
Design-Build
2@
1.7

2@
1.0

1@
0.2
Value engineering redesign of conventionally reinforced concrete waste treatment tanks originally designed by others. The two 1.0 MG tanks were originally designed to be circular. The others were originally designed as rectangular. All were converted to circular prestressed concrete tanks with horizontally and vertically post-tensioned walls and two-way post-tensioned membrane floors. Price includes walkways on tops of the walls and launders as applicable, and excavation and backfill, but not piping and appurtenances or redesign fees.

$1,150,00
The owner saved $315,000 as a result of our design.
20.9
Corporación Servicos Mirador
Norte, S.A.
Ciudad Modelo Water Tanks
Santo Domingo, Dominican Republic
Matsos & Arzeno, S.A.
September
1998 (B)
Design-Build
2@
2.0
Horizontal and vertical post-tensioned cast-in-place wall; not buried; post-tensioned membrane slab floor; post-tensioned two-way flat plate roof. Price includes structural design fee.

$459,385
each
24.3
Superior Metropolitan District
No. 1
Superior, CO
Low Zone Water Storage Tank
McLaughlin Water Engineers
October
1998 (B)
1.6 Horizontal and vertical post-tensioned wall; buried, includes excavation and backfill; post-tensioned floor and roof. Roof designed for allowing water to rise into the cone, 3-feet above the wall joint. Price dose not include $37,500 for 5 ft. of lime-treated structural fill below the tank.

$664,475 41.5
Castle Rock Development
Company
Meadows Yellow Zone Tank 12a
Castle Rock, CO
Meurer & Assoc., (Civil Engineer)
January
1999 (B)
4.0 Horizontal and vertical post-tensioned wall; buried, includes $177,000 for excavation and backfill; post-tensioned floor and roof. Price does not include $62,000 for lime-treated fill below the tank.

$980,000 24.5
City of Lafayette, CO
Yellow Zone Water Tank,
at the Baseline Road WTP
McLaughlin Water Engineers
August
1999 (B)
4.0 Horizontal and vertical post-tensioned wall; buried, includes excavation and backfill; post-tensioned floor and roof. Price includes a premium for an extremely tight site, without room for storage of the excavated materials.

$1,400,000 35.0
Superior Metropolitan District
No. 1
Rock Cr. WWTP, Superior, CO
Clarifier Tank and two Digester
Tanks
McLaughlin Water Engineers
September
1999 (B)
0.35
and


2@
0.5
Horizontal and vertical post-tensioned wall; buried, post-tensioned floor open top.

Horizontal and vertical post-tensioned digester walls; buried, with up to three feet of backfill over the post-tensioned two-way flat plate roofs; post-tensioned floor slabs.

Unknown, Bid as part of a $1,337,000 add'n to the Water Treatment Plant
Superior Metropolitan District
No. 1
Rock Cr. WWTP, Superior, CO
High Zone Water Storage Tank
McLaughlin Water Engineers
October
1999 (B)
0.5 Horizontal and vertical post-tensioned wall; buried, includes excavation and backfill; post-tensioned floor and roof. Roof designed for three feet of backfill plus H-20 trucks on the roof. Price does not include $78,500 for 5 ft. of lime-treated imported structural fill below the tank and exporting excess earth.

$457,180 91.4
Superior Metropolitan District No. 1
Rock Cr. WWTP, Superior, CO
McLaughlin Water Engineers
May
2000 (B)
0.5 Horizontal and vertical post-tensioned wall; buried, includes excavation and backfill; post-tensioned floor, open top.

Unknown, bid as part of a $3,600,000 add'n to the Waste Water Treatment Plant

Superior Metropolitan District No. 1
Superior, CO, Digester Tanks
McLaughlin Water Engineers
May
2000 (B)
2@
0.5
Horizontal and vertical post-tensioned wall; buried, includes excavation and backfill; post-tensioned floor and roof. Roof designed for three feet of backfill.

Unknown, bid as part of a $3,600,000 add'n to the Waste Water Treatment Plant

Town of Fraser
Maryvale Subdivision,
Grand County, CO
McLaughlin Water Engineers
June
2001 (B)
0.5 Horizontal and vertical post-tensioned wall; buried includes excavation and backfill; post-tensioned floor and roof. Roof designed for two feet of backfill and 75 psf snow load.

$620,000 1.24
City of Lafayette, CO
Lafayette Wastewater Treatment Plant
McLaughlin Water Engineers
October
2001 (B)
0.2,
and
0.4
A circular prestressed concrete primary clarifier, and a prestressed concrete secondary clarifier. Horizontal and vertical post-tensioned walls; buried; post-tensioned floors, open tops.

Unknown, bid as part of a $5,000,000 add'n to the Waste Water Treatment Plant

Jiamusi Municipal Auth.
City of Jiamusi,
People's Republic of China
Northeast Public Works Design
and Research Institute
January
2002 (B)
2@
3.0
Circular prestressed concrete potable water tanks. Horizontally and vertically post-tensioned wall, post-tensioned membrane floor with integral wall and column footings. As with all tanks built in China to date, these have all unbonded tendons, in the floors, walls and roofs. Buried with 2 ft. of backfill on roofs.

$481,900 8.0
Yingkou Waste Disposal Auth.
Yingkou WWTP,
People's Republic of China
Northeast Public Works Design
and Research Institute
February
2002 (B)
1.6,
and
1.5
A circular primary clarifier, a circular secondary clarifier. Horizontally and vertically post-tensioned walls, post-tensioned membrane floors with integral wall footings / foundations.

$220,000
and
$210,000
13.8
and
14.0
Panjin Waste Disposal Auth.
Panjin WWTP,
People's Republic of China
Northeast Public Works Design
and Research Institute
March
2002 (B)
1.5
A circular prestressed concrete secondary clarifier. Horizontally and vertically post-tensioned walls, post-tensioned structural floors with tension piers and integral wall footings / foundations.

$210,000
14.0
Jinzhou Waste Disposal Auth.
Jinzhou WWTP,
People's Republic of China
Northeast Public Works Design
and Research Institute
March
2002 (B)
1.6,
and
1.5
A circular clarifier. A circular secondary clarifier. Horizontally and vertically post-tensioned walls, post-tensioned structural floors with tension piers and integral wall footings / foundations.

$170,000
and
$160,000
10.6
and
10.7
Black Hawk - Central City Sanitation Dist.
WW Treatment Fac., Black Hawk, CO
Greeley and Hansen LLC
Spring
2003 (B)
2@
0.25
Two circular concrete prestressed concrete secondary clarifiers. Horizontally and vertically post-tensioned walls, post-tensioned floors. Open tops.



San Lorenzo-Cagus Water Supply Auth.
San Lorenzo Tank, Puerto Rico
Gregory L. Morris and Assoc. Engineers
Spring
2003
2.0 Horizontal and vertical post-tensioned wall; above ground, includes site preparation on; post-tensioned roof and membrane floor.

Unknown at this time
San Lorenzo-Cagus Water Supply Auth.
San Lorenzo Tank, Puerto Rico
Gregory L. Morris and Assoc. Engineers
Spring
2003
3.0 Horizontal and vertical post-tensioned wall; above ground, includes site preparation on; post-tensioned roof and membrane floor.

Unknown at this time
Town of Castle Rock
Castle Oaks Potable Water Tank
Castle Rock, CO
HDR Engineers, civil engineer
Summer
2003 (B)
9.8 A circular prestressed concrete potable water tank with a horizontally and vertically post-tensioned wall, post-tensioned membrane floor with integral wall and column footings. Above grade.

In design stage
City of Albuquerque, NM
Zamora Reservoir
Albuquerque, NM
Leedshill-Herkenhoff Engineers
Unknown
Pending Need,
Design Completed
4.0 Horizontally and vertically post-tensioned wall; buried, with 3 feet of backfill over the two-way flat-plate roof; post-tensioned floor slab. Price includes excavation and backfill, stubbed-out piping and appurtenances.

Not yet available